Using unique high-precision digital filter to eliminate baseline drift and other disturbances, avoid ECG waveform distortion and greatly enhance the anti-baseline drift capability to facilitate waveform detection
Availability: | |
---|---|
XRMD21011208
XINDRAY
12 Channel Dynamic Portable ECG Machine
Products feature
1. 8.4 inch (resolution: 800*600) color TFT display, optional touch screen
2. Supporting multi-language. Such as Chinese, English, Spanish, Polish
3. Support Chinese/English/other languages input
4. Print preview before printing
5. 12-lead simultaneous acquisition and amplification; Record the 12 ECG waveform simultaneous; all-digital and full-floating design.
6. 1:1 ratio for LCD screen wave-forms and output waveform, net-grid on screen and record paper are the same.
7. The latest 120 seconds 12-lead wave-forms recordable
8. automatic measurement and interpretation tested selectable
9. Up to 122 kinds of arrhythmia analysis
10. Manual,/Auto/ Rhythm working mode selectable
11. 3 Recording mode: Record and not printout, record and printout, no record only printout
Using unique high-precision digital filter to eliminate baseline drift and other disturbances, avoid ECG waveform distortion and greatly enhance the anti-baseline drift capability to facilitate waveform detection
Technical Specification:
Safety Standards | |
ISO 13485: 2003 approved, CE marking according to MDD93/42/EEC | |
Performance Specifications | |
Input Circuit: | Defibrillator protection built-in |
Lead: | Standard 12 leads |
Acquisition Mode: | 12 leads simultaneously |
A/D Converter: | 24 bits |
Measurement Range: | ±5mVpp |
Time Constant: | ≥5s |
Frequency Response | 0.05-150Hz |
Calibration Voltage | 1mV±3% |
Sensitivity: | 2.5,5,10,20(mm/mV) |
Input impedance: | ≥50MΩ |
Input Circuit Current: | ≤50uA |
Noise Level: | ≤15uVp-p |
Anti Baseline Drift: | Automatic |
Patient Leakage Current: | <10 uA(220V-240V) |
Patient Auxiliary Current | <0.1 uA(DC) |
Filter | EMG Filter:25Hz/35Hz/45Hz/OFF |
DFT Filter:0.05/0.10/0.2/0.5Hz | |
Lowpass Filter:150/100/75Hz | |
AC filter:50Hz/60Hz/OFF | |
Recording Mode: | Auto |
Manual | |
Rhythm | |
Rhythm Lead: | Any lead selectable |
Recorder: | Thermal printer |
Paper speed: | 5mm/s,10mm/s,12.5mm/s,25mm/s,50mm/s(±2%) |
Gain: | AGC,2.5mm/mV,5mm/mV,10mm/mV,20mm/mV,10/5mm/mV,20/10mm/mV |
Recorder Paper: | 210mmX30m,215mmX30m,210mmX140mm-150P,215mmX140mm-150P |
Record format: | 3×4,3×4+1R,3×4+3R,6×2,6×2+1R,12×1,12×1+T |
External input/output: | Input:≥100KΩ; sensitivity 10mm/V ±5% |
Output:≤100Ω; sensitivity 1V/mV ±5% |
12 Channel Dynamic Portable ECG Machine
Products feature
1. 8.4 inch (resolution: 800*600) color TFT display, optional touch screen
2. Supporting multi-language. Such as Chinese, English, Spanish, Polish
3. Support Chinese/English/other languages input
4. Print preview before printing
5. 12-lead simultaneous acquisition and amplification; Record the 12 ECG waveform simultaneous; all-digital and full-floating design.
6. 1:1 ratio for LCD screen wave-forms and output waveform, net-grid on screen and record paper are the same.
7. The latest 120 seconds 12-lead wave-forms recordable
8. automatic measurement and interpretation tested selectable
9. Up to 122 kinds of arrhythmia analysis
10. Manual,/Auto/ Rhythm working mode selectable
11. 3 Recording mode: Record and not printout, record and printout, no record only printout
Using unique high-precision digital filter to eliminate baseline drift and other disturbances, avoid ECG waveform distortion and greatly enhance the anti-baseline drift capability to facilitate waveform detection
Technical Specification:
Safety Standards | |
ISO 13485: 2003 approved, CE marking according to MDD93/42/EEC | |
Performance Specifications | |
Input Circuit: | Defibrillator protection built-in |
Lead: | Standard 12 leads |
Acquisition Mode: | 12 leads simultaneously |
A/D Converter: | 24 bits |
Measurement Range: | ±5mVpp |
Time Constant: | ≥5s |
Frequency Response | 0.05-150Hz |
Calibration Voltage | 1mV±3% |
Sensitivity: | 2.5,5,10,20(mm/mV) |
Input impedance: | ≥50MΩ |
Input Circuit Current: | ≤50uA |
Noise Level: | ≤15uVp-p |
Anti Baseline Drift: | Automatic |
Patient Leakage Current: | <10 uA(220V-240V) |
Patient Auxiliary Current | <0.1 uA(DC) |
Filter | EMG Filter:25Hz/35Hz/45Hz/OFF |
DFT Filter:0.05/0.10/0.2/0.5Hz | |
Lowpass Filter:150/100/75Hz | |
AC filter:50Hz/60Hz/OFF | |
Recording Mode: | Auto |
Manual | |
Rhythm | |
Rhythm Lead: | Any lead selectable |
Recorder: | Thermal printer |
Paper speed: | 5mm/s,10mm/s,12.5mm/s,25mm/s,50mm/s(±2%) |
Gain: | AGC,2.5mm/mV,5mm/mV,10mm/mV,20mm/mV,10/5mm/mV,20/10mm/mV |
Recorder Paper: | 210mmX30m,215mmX30m,210mmX140mm-150P,215mmX140mm-150P |
Record format: | 3×4,3×4+1R,3×4+3R,6×2,6×2+1R,12×1,12×1+T |
External input/output: | Input:≥100KΩ; sensitivity 10mm/V ±5% |
Output:≤100Ω; sensitivity 1V/mV ±5% |