1.Automatic storage of test results, review and print all parameters in test results;
2. Color touch screen, all parameters and histograms can be displayed in the same screen;
3.Support the expansion of external devices such as mouse, keyboard and printer;
4.Optical five reference ranges: newborn, children, adult women, adult men, and general use;
5.Multiple clogging elimination methods: high-pressure burning jewel hole, high-pressure reverse rinsing and soaking;
Availability: | |
---|---|
XRME210301103
XINDRAY
Feature:
1.Automatic storage of test results, review and print all parameters in test results;
2. Color touch screen, all parameters and histograms can be displayed in the same screen;
3.Support the expansion of external devices such as mouse, keyboard and printer;
4.Optical five reference ranges: newborn, children, adult women, adult men, and general use;
5.Multiple clogging elimination methods: high-pressure burning jewel hole, high-pressure reverse rinsing and soaking;
6.Automatic cleaning of sample probe;
7.By VGA interface, external projector or external display screen can be connected;
8.Chinese and English system language;
9.Built-in thermal printer, serial port printing and other printing methods;
10.With quality control management and calibration management function;
11.Use the cyanide-free SFT method (environmentally friendly) to measure hemoglobin;
12.Floating boundary algorithm and histogram abnormal prompt function.
1.Test parameters: WBC 3-part differential counting, 23 parameters (including WBC, RBC, PLT color histogram);
2.Measurement principle: counting by electrical impedance method, colorimetric method to measure HGB;
3.Quality control method: L-J, automatic drawing and printing of quality control charts;
4.Sample volume: trace detection, 10μL peripheral blood or anticoagulant blood, pre-dilution mode 20μL;
5.Precision: WBC (white blood cell) CV≤4.0%, RBC (red blood cell) CV≤2.0%, HGB (hemoglobin) CV≤2.0%, PLT (platelet) CV≤8.0%, MCV (average red blood cell volume) CV≤3.0% ;
6.Accuracy: the allowable relative deviation range: WBC≤±15%, RBC≤±6.0%, HGB≤±6.0%, PLT≤±20.0%, HCT (hematocrit)≤±9.0%;
7.Blank count: WBC≤0.5×109/L, RBC≤0.05×1012/L, HGB≤2.0g/L, PLT≤10.0×109/L;
8.Carry-over: WBC≤3.5%, RBC≤2.0%, HGB≤2.0%, PLT≤5.0%;
9.Linearity deviation: WBC≤±5%, RBC≤±5%, HGB≤±3%, PLT≤±10%;
10.Related coefficient: WBC≥0.990, RBC≥0.990, HGB≥0.990, PLT≥0.990;
11.Display: color LCD touch screen;
12.Detection channel: dual channel;
13.Test speed: 35 (or 60) specimens/hour, continuous working for 24 hours;
14.Data storage: It can automatically store more than 30,000 groups of complete results (each result has three histograms);
15.Interface: RS232 interface, VGA interface;
16.Power supply: ~100V-240V; 50/60Hz.
Feature:
1.Automatic storage of test results, review and print all parameters in test results;
2. Color touch screen, all parameters and histograms can be displayed in the same screen;
3.Support the expansion of external devices such as mouse, keyboard and printer;
4.Optical five reference ranges: newborn, children, adult women, adult men, and general use;
5.Multiple clogging elimination methods: high-pressure burning jewel hole, high-pressure reverse rinsing and soaking;
6.Automatic cleaning of sample probe;
7.By VGA interface, external projector or external display screen can be connected;
8.Chinese and English system language;
9.Built-in thermal printer, serial port printing and other printing methods;
10.With quality control management and calibration management function;
11.Use the cyanide-free SFT method (environmentally friendly) to measure hemoglobin;
12.Floating boundary algorithm and histogram abnormal prompt function.
1.Test parameters: WBC 3-part differential counting, 23 parameters (including WBC, RBC, PLT color histogram);
2.Measurement principle: counting by electrical impedance method, colorimetric method to measure HGB;
3.Quality control method: L-J, automatic drawing and printing of quality control charts;
4.Sample volume: trace detection, 10μL peripheral blood or anticoagulant blood, pre-dilution mode 20μL;
5.Precision: WBC (white blood cell) CV≤4.0%, RBC (red blood cell) CV≤2.0%, HGB (hemoglobin) CV≤2.0%, PLT (platelet) CV≤8.0%, MCV (average red blood cell volume) CV≤3.0% ;
6.Accuracy: the allowable relative deviation range: WBC≤±15%, RBC≤±6.0%, HGB≤±6.0%, PLT≤±20.0%, HCT (hematocrit)≤±9.0%;
7.Blank count: WBC≤0.5×109/L, RBC≤0.05×1012/L, HGB≤2.0g/L, PLT≤10.0×109/L;
8.Carry-over: WBC≤3.5%, RBC≤2.0%, HGB≤2.0%, PLT≤5.0%;
9.Linearity deviation: WBC≤±5%, RBC≤±5%, HGB≤±3%, PLT≤±10%;
10.Related coefficient: WBC≥0.990, RBC≥0.990, HGB≥0.990, PLT≥0.990;
11.Display: color LCD touch screen;
12.Detection channel: dual channel;
13.Test speed: 35 (or 60) specimens/hour, continuous working for 24 hours;
14.Data storage: It can automatically store more than 30,000 groups of complete results (each result has three histograms);
15.Interface: RS232 interface, VGA interface;
16.Power supply: ~100V-240V; 50/60Hz.