Technical Specification:
Assay Model | Random access with direct reading system |
Method | End point, Kinetic, Fixed time, Immunoturbidimetric, 1-2 reagent, |
Assay Item | 40 assays |
Throughput | 160 tests/hour |
Test Menu | Liver Function, Renal Function, Blood Fat, Cardiac Muscle, Saccharide, etc |
Sample Position | 30 |
Including standard, control and STAT; either serum cup or primary tube available | |
Sample Volume | 1~100μl, 0.1μl/ step |
Reagent Position | 40 |
Reagent Volume | R1: 1~400μl, 1μl/step, R2:1~400μl/step |
1~500μl in 0.1μl/ step (Minimum 50μl/test design on request) | |
Reagent/Sample Probe | With liquid level sensor, collision sensor, Teflon coating and automatic washing |
station | |
Mixing System | No touching mixing technology, lower carry-over and lower water consumption |
Cooling System | Reliable and Stable 2-8°C Chamber |
Reaction Time | 0~999 seconds |
Cuvette | High quality UV-transmitted plastic cuvette. Real time water blank to ensure the quality of the cuvettes |
Cuvette Washing | 5 channels with detergent washing available |
Alarm | Automatic alarm for malfunction (eg: collision, reagent/ sample insufficiency, full waste container, etc) |
Calibration | Linear, Non-linear, Multi point, K factor |
Sample Dilution/Retest | Sample can be diluted and retested if results are out of range or sample is insufficient. Also with calibrator auto diluting function |
Wavelength | 340~810nm |
Light Source | Halogen lamp |
Absorbance Resolution | 0.0001A |
Absorbance Accuracy | ±0.0003A (0~2.5A) |
Repeatability (CV%) | ≦2% |
Quality Control | Levy-Jennings quality control program at 3 levels |
Bar Code | Optional (external bar code reader) |
Printer | Multiple report formats available |
Language | English, French, Spanish, German, Russian, etc. |
System | Windows XP, Windows 7 or Windows 8 |
Power supply | 220V/50Hz, or 110V/60Hz (optional) |
Dimension | 65*53*52cm |
Weight | 40kg |
Product features
Chemistry analyzers can be bench top devices or placed on a cart; other systems require floor space. They are used to determine the concentration of certain metabolites, electrolytes, proteins, and/or drugs in samples of serum, plasma, urine, cerebrospinal fluid, and/or other body fluids
Advantages:
1. Good quality and reasonable price.
2. Strict quality control.
3. Excellent service.
Technical Specification:
Assay Model | Random access with direct reading system |
Method | End point, Kinetic, Fixed time, Immunoturbidimetric, 1-2 reagent, |
Assay Item | 40 assays |
Throughput | 160 tests/hour |
Test Menu | Liver Function, Renal Function, Blood Fat, Cardiac Muscle, Saccharide, etc |
Sample Position | 30 |
Including standard, control and STAT; either serum cup or primary tube available | |
Sample Volume | 1~100μl, 0.1μl/ step |
Reagent Position | 40 |
Reagent Volume | R1: 1~400μl, 1μl/step, R2:1~400μl/step |
1~500μl in 0.1μl/ step (Minimum 50μl/test design on request) | |
Reagent/Sample Probe | With liquid level sensor, collision sensor, Teflon coating and automatic washing |
station | |
Mixing System | No touching mixing technology, lower carry-over and lower water consumption |
Cooling System | Reliable and Stable 2-8°C Chamber |
Reaction Time | 0~999 seconds |
Cuvette | High quality UV-transmitted plastic cuvette. Real time water blank to ensure the quality of the cuvettes |
Cuvette Washing | 5 channels with detergent washing available |
Alarm | Automatic alarm for malfunction (eg: collision, reagent/ sample insufficiency, full waste container, etc) |
Calibration | Linear, Non-linear, Multi point, K factor |
Sample Dilution/Retest | Sample can be diluted and retested if results are out of range or sample is insufficient. Also with calibrator auto diluting function |
Wavelength | 340~810nm |
Light Source | Halogen lamp |
Absorbance Resolution | 0.0001A |
Absorbance Accuracy | ±0.0003A (0~2.5A) |
Repeatability (CV%) | ≦2% |
Quality Control | Levy-Jennings quality control program at 3 levels |
Bar Code | Optional (external bar code reader) |
Printer | Multiple report formats available |
Language | English, French, Spanish, German, Russian, etc. |
System | Windows XP, Windows 7 or Windows 8 |
Power supply | 220V/50Hz, or 110V/60Hz (optional) |
Dimension | 65*53*52cm |
Weight | 40kg |