Availability: | |
---|---|
XRMD21010708
XINDRAY
Infant Phototherapy Incubator
Product features
Two control modes: Air mode and baby mode controlled by micro-computer;
Set temperature, air temperature, baby temperature is displayed separately;
Humidity concentration system;
Inclination of bassinet is adjustable;
Failure alarm indication;
RS-232 connector;
Oxygen input interface;
Configured with fixed neonate bilirubin phototherapy equipment
Configured with fixed neonate bilirubin phototherapy equipment with SMD LED blue lights under the bassinet;
Low noise DC motor
Specification:
1.Power requirement: AC220V-230V/50Hz or AC 110-120V/50-60Hz,1000VA
2.Control range of air temperature: 25°C-37°C(override mode: 37°C-39°C is optional)
Control range of baby temperature: 34°C-37°C(override mode: 37°C-38°C is optional)
3.Accuracy of skin temperature sensor: ±0.2°C
Variability of temperature: ≦0.5°C
4.Uniformity of temperature: ≦0.8°C (mattress is on the horizontal position)
5.The average value of total irradiance for bilirubin max of phototherapy equipment:
≧640μ W/c㎡ (blue fluorescent lamp)
≧1300μ W/c㎡(blue LED)
Standard Configuration:
Main body, mobile cabinet, temperature controller, Hood, I. V. Pole with shelf, Skin temperature sensor, mattress.
Optional Configuration:
“>37°C”temperature override mode function, Vertical height adjustment stand(VHA stand), Weighing system, Neonate Bilirubin Phototherapy Equipment with blue LED as upper light source and Disposable skin temperature sensor, SpO2.
Product Packaging:
Package: Main body and Cabinet are packed into separate cartons
Size (Main body): 1085mm*640mm*910mm,78kgs;
(Cabinet): 1125mm*665mm*725mm, 68kgs
Infant Phototherapy Incubator
Product features
Two control modes: Air mode and baby mode controlled by micro-computer;
Set temperature, air temperature, baby temperature is displayed separately;
Humidity concentration system;
Inclination of bassinet is adjustable;
Failure alarm indication;
RS-232 connector;
Oxygen input interface;
Configured with fixed neonate bilirubin phototherapy equipment
Configured with fixed neonate bilirubin phototherapy equipment with SMD LED blue lights under the bassinet;
Low noise DC motor
Specification:
1.Power requirement: AC220V-230V/50Hz or AC 110-120V/50-60Hz,1000VA
2.Control range of air temperature: 25°C-37°C(override mode: 37°C-39°C is optional)
Control range of baby temperature: 34°C-37°C(override mode: 37°C-38°C is optional)
3.Accuracy of skin temperature sensor: ±0.2°C
Variability of temperature: ≦0.5°C
4.Uniformity of temperature: ≦0.8°C (mattress is on the horizontal position)
5.The average value of total irradiance for bilirubin max of phototherapy equipment:
≧640μ W/c㎡ (blue fluorescent lamp)
≧1300μ W/c㎡(blue LED)
Standard Configuration:
Main body, mobile cabinet, temperature controller, Hood, I. V. Pole with shelf, Skin temperature sensor, mattress.
Optional Configuration:
“>37°C”temperature override mode function, Vertical height adjustment stand(VHA stand), Weighing system, Neonate Bilirubin Phototherapy Equipment with blue LED as upper light source and Disposable skin temperature sensor, SpO2.
Product Packaging:
Package: Main body and Cabinet are packed into separate cartons
Size (Main body): 1085mm*640mm*910mm,78kgs;
(Cabinet): 1125mm*665mm*725mm, 68kgs