Feature:
1. Three working modes: Rate mode, time-volume mode, dosage-weight mode.
2. Unique Human Voice Alarm system and accurate injection rate make the injection process safer and more reliable.
3. Have store many brands syringes, Automatically calibration and compatible with any brand syringes.
4. Large LCD screen displays working status.
5. KVO and Bolus functions.
6. Two channels can work independently or together.
Specification:
Model | XRME220206366 |
Injection Rate | 50(60)ml Syringe 0.1ml/h---999.9ml/h (0.1ml/h step) 1000ml/h---1500ml/h (1ml/h step) |
30ml Syringe 0.1ml/h---900ml/h (0.1ml/h step) | |
20ml Syringe 0.1ml/h---600ml/h (0.1ml/h step) | |
10ml Syringe 0.1ml/h---300ml/h (0.1ml/h step) | |
Rate Accuracy | Within±3% (after correct calibration) |
Mechanical Accuracy | Within±2% |
Purge Rate | 50(60)ml Syringe: 1500ml/h |
30ml Syringe: 900ml/h | |
20ml Syringe: 600ml/h | |
10ml Syringe: 300ml/h | |
Bolus Rate | 50(60)ml Syringe: 1200ml/h |
30ml Syringe: 720ml/h | |
20ml Syringe: 480ml/h | |
10ml Syringe: 240ml/h | |
Anti-Bolus | YES |
Volume Limit | 0.1ml---9999.9ml (0.1ml step) |
Total Injection | 0.1ml---9999.9ml (0.1ml step) |
Maximum infusion pressure | 150kPa |
Occlusion | High 800mmHg±200mmHg (106.7kPa±26.7kPa) |
Medium 500mmHg±100mmHg (66.7kPa±13.3kPa) | |
Low 300mmHg±100mmHg (40.7kPa±13.3kPa) | |
Audible and Visible Alarms | Occlusion ,Equipment failure, Software Exception, Injection finish, Limited finished, Battery running out, Improperly installed, Abnormal operation etc. |
Power Source | 100-240Vac, 50/60Hz; Internal rechargeable Li battery, capacity≥1,800mAh, voltage=11.1V, 4 hours backup time at the rate of 25ml/h (appointed medium rate in IEC60601-2-24) for the new battery charged for 12hours. To facilitate the use in some special occasions, the machine's DC outlet can be an external DC 12V 2A standby power supply. |
KVO Speed | 0.1~5ml/h (0.1ml/h step) |
Power Consumption | 35VA |
Fuse: | T2AH/250V, 2pcs installed |
Equipment Classification | Class II, internal power supply, Type CF |
IP Classification | IPX2 |
Operation Environment | a) Ambient temperature: +5℃~+40℃ |
b) Relative humidity: 20%~90% | |
c) Atmospheric pressure: 86.0kPa~106.0kPa | |
Transport & Storage Condition | a) Ambient temperature: -30℃~+55℃ |
b) Relative Humidity: ≤95% | |
c) Atmospheric pressure: 50.0kPa~106.0kPa | |
Syringe | Compatible with 10ml, 20ml, 30ml, 50/60ml syringe of any brands after correct calibration |
Syringe maximum value( under single fault condition) | 1ml |
Dimension | 280mm(L) x 255mm(W) x 205mm(H) |
Net Weight | 3.6Kg |
Package Reference | 1pc Carton: 4.6Kg, 34cm(L) x 32cm(W) x 26cm(H) |
2pcs Carton: 9.2Kg, 76cm(L) x 30cm(W) x 36cm(H) |