Feature:
12.1” TFT screen displays the ventilation parameters, alarm information, and oscillograms, make every operation more easily.
Multiple ventilation mode can meet different clinical requirements.( IPPV, A/C, PCV, SIMV,PSV, SPONT/CPAP,SIGH,MANUAL)
3 oscillograms for your choice, 2 of them can be displayed on the screen at the same time.
Humidifier can heat and wet breathing gas, makes it comfortable for patient to breathe.
Rapid oxygen supply,automatically offer high flow rate oxygen within two minutes
High temperature resistance breathing circuit is reusable and anti-pollution.
Specification:
Ventilation mode | |
IPPV, A/C, PCV, SIMV, SPONT/CPAP, PSV, SIGH, MANU | |
Ventilator parameter | |
Tidal volume (Vt) | 0 ~ 2000 mL |
Frequency (Freq) | 1 min ~ 100 min |
Oxygen concentration | 21 % ~ 100 % |
I:E | 4 : 1 ~ 1 : 8 |
PEEP | 0 cmH2O ~ 40 cmH2O |
Pressure limit | 20 cmH2O ~ 100 cmH2O |
Pressure triggering sensitivity(Ptr) | -20 cmH2O ~ 0 cmH2O (Based on PEEP) |
Flow triggering sensitivity(Ftr) | 0.5 cmH2O ~ 30 cmH2O |
SIGH | 0 (off) 1/100 ~ 5/100 |
Apnea ventilation | OFF, 5 s ~ 60 s |
Monitoring parameter | |
Frequency (Freq) | 0/min ~ 100/min |
Tidal volume (Vt) | 0 mL ~ 2500 mL |
MV | 0 L/min ~ 99 L/min |
Airway pressure | 0 cmH2O ~ 100 cmH2O |
Dynamic lung compliance monitoring | 1 mL/cmH2O ~ 1000 mL/cmH2O |
Oxygen concentration | 15 % ~ 100 % |
Packing size | |
Main engine: L 560 * W 560 * H 605 mm | |
G.W. : 40 KG, N.W. : 22 KG | |
Air compressor: L 683* W 687 * H 1140 mm | |
G.W. : 105 KG, N.W. : 70 KG | |
Alarm and protection | |
The AC power failure alarm | Power failure or no connection |
Internal backup battery low voltage alarm | ≤ 11.3 ± 0.3 V |
No tidal volume | No tidal volume within 6 s |
High minute volume alarm | 5 L/min ~ 99 L/min |
Low minute volume alarm | 1 L/min ~ 30 L/min |
High airway pressure alarm | 20 cmH2O ~ 100 cmH2O |
Low airway pressure alarm | 0 cmH2O ~ 20 cmH2O |
High oxygen concentration alarm | 19 % ~ 100 % |
Low oxygen concentration alarm | 18 % ~ 99 % |
Continuous pressure alarm | (PEEP + 1.5 cmH2O) over 16s |
Suffocation warning | 5 ~ 60 s |
Fan error | Show on screen |
Oxygen deficit | Show on screen |
The maximum limited pressure | < 12.5 kPa |
Working condition | |
Gas source | O2, Air |
Pressure | 280 kPa - 600 kPa |
Voltage | 220 V ± 22 V |
Power frequency | 50 Hz ± 1 Hz |
Input power | 900 VA(With air compressor) 250 VA(Without air compressor) |
Oscillogram | |
P-T(Pressure-Time) F-T(Flow-Time) P-V Loop(Pressure-Volume Loop) |