Microprocessor based servo controlled temperature system |
Microprocessor based servo controlled temperature system |
Availability: | |
---|---|
XRME220210370
XINDRAY
Feature:
Microprocessor based servo controlled temperature system
Three modes: pre-warm. manual or automatic
Set temperature and skin temperature display separately
Special design inclined heater head is more convenience for X rays
Carbon steel heater for more effectivity
Audible and visual Alarm functions:
Power failure, temperature deviation, temperature sensor failure, skin temperature failure, over temperature
APGAR timer to record therapy time
Convenient X-ray cassette under infant bed
Electric inclination of infant bed
LED observation light adjustable, brightness adjustable
Four Transparent protector folded with 2 infusion seals
LED phototherapy unit, Oxygen supply system
Bigger infant bed
Built in low pressure aspirator
With RS-232 connector, 2 trays and 2 drawers
Specification:
Technical data | |
Power supply | Ac110/220v 60/50hz |
Power input | 1100VA |
Environment temperature | 18℃-30℃ |
Environment relative humidity | 30%-75% |
Atmospheric pressure | 700-1060hpa |
Environment air velocity of flow | <0.3m/s |
skin temperature control range | 32℃-38℃ |
Skin temperature control accuracy | ≤0.5℃ |
Skin temperature sensor accuracy | 土0.3℃ |
Mattress temperature uniformity | <2℃ |
Infant Bed tilt angle | ±12° |
Warm-up time(from25℃) | <30min |
Heater head horizontal | ±90° |
LED observation light | 3W |
Distance from heater to mattress | 80cm |
Mattress size | 78cm X 64cm |
Timer range | 0~99h59min |
LED phototherapy light 36cm | 620-2800μw/c㎡ |
LED phototherapy light 50cm | 400-1620μw/c㎡ |
Max vacuum adjustable | ≥-25kpa(-188mmHg) |
Storage bottle | 1000mL |
Oxygen cylinder | 6L X 2 |
Oxygen flow meter | 0-10L/min |
Feature:
Microprocessor based servo controlled temperature system
Three modes: pre-warm. manual or automatic
Set temperature and skin temperature display separately
Special design inclined heater head is more convenience for X rays
Carbon steel heater for more effectivity
Audible and visual Alarm functions:
Power failure, temperature deviation, temperature sensor failure, skin temperature failure, over temperature
APGAR timer to record therapy time
Convenient X-ray cassette under infant bed
Electric inclination of infant bed
LED observation light adjustable, brightness adjustable
Four Transparent protector folded with 2 infusion seals
LED phototherapy unit, Oxygen supply system
Bigger infant bed
Built in low pressure aspirator
With RS-232 connector, 2 trays and 2 drawers
Specification:
Technical data | |
Power supply | Ac110/220v 60/50hz |
Power input | 1100VA |
Environment temperature | 18℃-30℃ |
Environment relative humidity | 30%-75% |
Atmospheric pressure | 700-1060hpa |
Environment air velocity of flow | <0.3m/s |
skin temperature control range | 32℃-38℃ |
Skin temperature control accuracy | ≤0.5℃ |
Skin temperature sensor accuracy | 土0.3℃ |
Mattress temperature uniformity | <2℃ |
Infant Bed tilt angle | ±12° |
Warm-up time(from25℃) | <30min |
Heater head horizontal | ±90° |
LED observation light | 3W |
Distance from heater to mattress | 80cm |
Mattress size | 78cm X 64cm |
Timer range | 0~99h59min |
LED phototherapy light 36cm | 620-2800μw/c㎡ |
LED phototherapy light 50cm | 400-1620μw/c㎡ |
Max vacuum adjustable | ≥-25kpa(-188mmHg) |
Storage bottle | 1000mL |
Oxygen cylinder | 6L X 2 |
Oxygen flow meter | 0-10L/min |