It is a compact, durable, light weighted defibrillator Asynchronous outer defibrillation, Audible and visible reminders come with sine wave: monophasic and options for Biphasic technology.
Technical Specification:
Defibrillator:
(1)Defibrillator type: Manual, Synchronized, A synchronized,
(2)Output waveform: Monophonic technology /Biphasic technology (optional)
(3)Energy accuracy: <+1%
(4)Energy selection: 0,3,5,7,10,20,30,50,100,200,300,360 joule (nominal at a resistance of 50)
(5)Charging time: Maximum 8 seconds to 360 Joules
(6)Standard Adult/Pediatric Paddles Reusable external adult paddles (pediatric paddles integrated)
Power requirements:
(a) AC Power supply 110V, 60 Hz /220V, 50 Hz
(b) Vehicle Voltage DC 12V
Internal Battery Backup:
(1) Battery type Rechargeable lead-acid battery/ lithium battery (optional)
(2) Charging time Time-Minimum of 4 hours for full charging
(3) Battery charging During AC Power Supply operation of the device.
(4) Charging /Low Battery Indication Red LED
(5) Battery Capacity 100% of the battery will provide 120 min of monitoring; and 30 discharges at 360 joules.
Display: LED Dimensions 7’diagonal {155mm*88mm}
Type: High resolution true-color graphic LED
BOARD DISPLAY:
1) CLEAR BUTTON Clear the energy selection and
discharge the energy by inside circuit.
2) CHARGE to indicate charging process for the defibrillator
battery. The lamp went out if full capacity.
3) BATTERY INDICATOR To show the DC work of inner battery.
4) DEFIBRILLATING ENERGY INDICATOR
5) ENERGY SELECTOR To select the energy of the heart defibrillating treatment.
Dimensions: L320 x W205 x H410
Weight: 9.8kg
Medical Heart Defibrillator Price
Products feature
It is a compact, durable, light weighted defibrillator Asynchronous outer defibrillation, Audible and visible reminders come with sine wave: monophasic and options for Biphasic technology.
Technical Specification:
Defibrillator:
(1)Defibrillator type: Manual, Synchronized, A synchronized,
(2)Output waveform: Monophonic technology /Biphasic technology (optional)
(3)Energy accuracy: <+1%
(4)Energy selection: 0,3,5,7,10,20,30,50,100,200,300,360 joule (nominal at a resistance of 50)
(5)Charging time: Maximum 8 seconds to 360 Joules
(6)Standard Adult/Pediatric Paddles Reusable external adult paddles (pediatric paddles integrated)
Power requirements:
(a) AC Power supply 110V, 60 Hz /220V, 50 Hz
(b) Vehicle Voltage DC 12V
Internal Battery Backup:
(1) Battery type Rechargeable lead-acid battery/ lithium battery (optional)
(2) Charging time Time-Minimum of 4 hours for full charging
(3) Battery charging During AC Power Supply operation of the device.
(4) Charging /Low Battery Indication Red LED
(5) Battery Capacity 100% of the battery will provide 120 min of monitoring; and 30 discharges at 360 joules.
Display: LED Dimensions 7’diagonal {155mm*88mm}
Type: High resolution true-color graphic LED
BOARD DISPLAY:
1) CLEAR BUTTON Clear the energy selection and
discharge the energy by inside circuit.
2) CHARGE to indicate charging process for the defibrillator
battery. The lamp went out if full capacity.
3) BATTERY INDICATOR To show the DC work of inner battery.
4) DEFIBRILLATING ENERGY INDICATOR
5) ENERGY SELECTOR To select the energy of the heart defibrillating treatment.
Dimensions: L320 x W205 x H410
Weight: 9.8kg