Availability: | |
---|---|
XRMD21011307
XINDRAY
Portable Mobile Automatic External Aed Defibrillator
Products feature
Automatic External Defibrillator is a safe, easy to use defibrillation device. The unit is lightweight and mobile and can be used in situations where there could be several minutes before the arrival of advanced life support (ALS) personnel.
Features:
Three-step defibrillation process
Two-button operation
Extensive voice and visual prompts for the operator
Biphasic energy output
Lock-out protection to prevent inadvertent defibrillation
Continuous event recording for reporting each use to a printer or computer
Weekly self-test to ensure readiness
Color LCD screen
Adult and Pediatric defibrillation
CPR coaching (Optional)
Technical Specification:
Defibrillator | |
Output | Biphasic Truncated exponential |
Energy Sequence(adult) | 150/150/200(Default) |
Energy Sequence(Pediatric) | 50/70/85(Default) |
Charge Time | 10 sec. to 200J |
Analysis Time | 9 sec. |
The maximum time from the initiation | Less than 30 seconds |
The maximum time from initially | Less than 35 seconds |
Audible Prompts | 19 audible prompts |
Visual Prompts | LED/LCD |
Controls | six buttons-On/Off, Shock, and 4 software-configurable buttons |
Output Energy Accuracy | ±15% into any impedance from 25 to 175Ω |
The Maximum Voltage | 1800±20V |
Output disabled when the PATIENT | 20Ω to 200Ω |
Recovery of the ECG input after | <10s |
Physical | |
Dimensions | 225*200*85mm |
Weight | 2.0kg |
Operating Temperature | 0℃ to 40℃ |
Operating Humidity | Relative humidity between 30% and 95% (non-condensing) |
Altitude | -300 to 15,000 ft( -91m to 4573m) |
Pressure | 102.4kPa~57.2kPa(768mmHg~429mmHg) |
Storage Temperature(without battery) | -20℃ to 55℃ |
Storage Humidity(without battery) | Up to 93% (non-condensing) |
Particle and Water Ingress | IP24 |
Electrical Isolation | |
Power | Unit operates on internal battery only |
External Electrical Connections | No external devices are attached to the unit |
Risk Current Category | Internally powered equipment with defibrillator-proof BF type patient |
Portable Mobile Automatic External Aed Defibrillator
Products feature
Automatic External Defibrillator is a safe, easy to use defibrillation device. The unit is lightweight and mobile and can be used in situations where there could be several minutes before the arrival of advanced life support (ALS) personnel.
Features:
Three-step defibrillation process
Two-button operation
Extensive voice and visual prompts for the operator
Biphasic energy output
Lock-out protection to prevent inadvertent defibrillation
Continuous event recording for reporting each use to a printer or computer
Weekly self-test to ensure readiness
Color LCD screen
Adult and Pediatric defibrillation
CPR coaching (Optional)
Technical Specification:
Defibrillator | |
Output | Biphasic Truncated exponential |
Energy Sequence(adult) | 150/150/200(Default) |
Energy Sequence(Pediatric) | 50/70/85(Default) |
Charge Time | 10 sec. to 200J |
Analysis Time | 9 sec. |
The maximum time from the initiation | Less than 30 seconds |
The maximum time from initially | Less than 35 seconds |
Audible Prompts | 19 audible prompts |
Visual Prompts | LED/LCD |
Controls | six buttons-On/Off, Shock, and 4 software-configurable buttons |
Output Energy Accuracy | ±15% into any impedance from 25 to 175Ω |
The Maximum Voltage | 1800±20V |
Output disabled when the PATIENT | 20Ω to 200Ω |
Recovery of the ECG input after | <10s |
Physical | |
Dimensions | 225*200*85mm |
Weight | 2.0kg |
Operating Temperature | 0℃ to 40℃ |
Operating Humidity | Relative humidity between 30% and 95% (non-condensing) |
Altitude | -300 to 15,000 ft( -91m to 4573m) |
Pressure | 102.4kPa~57.2kPa(768mmHg~429mmHg) |
Storage Temperature(without battery) | -20℃ to 55℃ |
Storage Humidity(without battery) | Up to 93% (non-condensing) |
Particle and Water Ingress | IP24 |
Electrical Isolation | |
Power | Unit operates on internal battery only |
External Electrical Connections | No external devices are attached to the unit |
Risk Current Category | Internally powered equipment with defibrillator-proof BF type patient |