● Microcomputer control
● Precise power control , applied to general surgery, Orthopedic surgery, laparoscopic surgery.
● Isolated output
● Patient plate connection warning
● Auto-protect of short circuit. Mono-polar and bipolar outputs
● Automatic system self-checking
Availability: | |
---|---|
XRME220210304
XINDRAY
Portably High Frequency Electrosurgical Unit
Feature:
● Microcomputer control
● Precise power control , applied to general surgery, Orthopedic surgery, laparoscopic surgery.
● Isolated output
● Patient plate connection warning
● Auto-protect of short circuit. Mono-polar and bipolar outputs
● Automatic system self-checking.
Technical Specifications | ||
Power: | 220V±22V,50/60 Hz(110V±11V,50/60Hz) | |
Operating Frequency: | Monopolar: 330/430 KHz | |
Bipolar: 1M KHZ | ||
Output Power | 300W | |
Power Rating: | 800VA±10% | |
Operating Mode: | Monopolar Cut | |
Pure Cut: | 0~300W(Load 500Ω) | |
Blend 1: | 0~250W(Load 500Ω) | |
Blend 2: | 0~100W(Load 500Ω) | |
Monopolar Coag | ||
Contact Coag: | 0~120W(Load 500Ω) | |
Forced Coag: | 0~100W(Load 500Ω) | |
Soft Coag: | 0~50W(Load 500Ω) | |
Bipolar | ||
Bipolar Coagulation: | 0~100W(Load 100Ω) | |
Bipolar AUTO | 0~100W(Load 100Ω) | |
Power Consumption: | 800VA±10% | |
Surgery Type | For Variety of Operations , Endoscopy | |
Dimension L*W*H | 380mm*380mm*160mm | |
Weight | 10kg |
Standard Configuration | ||
Description | Quantity | Picture |
High frequency Electrosurgical unit | 1 |
|
Power Cable | 1 |
|
Disposable electrosurgical control pencil | 5 |
|
Disposable electro plate | 1 | |
Bipolar forceps | 1 |
|
Single foot step | 1 |
|
Double foot step | 1 |
Portably High Frequency Electrosurgical Unit
Feature:
● Microcomputer control
● Precise power control , applied to general surgery, Orthopedic surgery, laparoscopic surgery.
● Isolated output
● Patient plate connection warning
● Auto-protect of short circuit. Mono-polar and bipolar outputs
● Automatic system self-checking.
Technical Specifications | ||
Power: | 220V±22V,50/60 Hz(110V±11V,50/60Hz) | |
Operating Frequency: | Monopolar: 330/430 KHz | |
Bipolar: 1M KHZ | ||
Output Power | 300W | |
Power Rating: | 800VA±10% | |
Operating Mode: | Monopolar Cut | |
Pure Cut: | 0~300W(Load 500Ω) | |
Blend 1: | 0~250W(Load 500Ω) | |
Blend 2: | 0~100W(Load 500Ω) | |
Monopolar Coag | ||
Contact Coag: | 0~120W(Load 500Ω) | |
Forced Coag: | 0~100W(Load 500Ω) | |
Soft Coag: | 0~50W(Load 500Ω) | |
Bipolar | ||
Bipolar Coagulation: | 0~100W(Load 100Ω) | |
Bipolar AUTO | 0~100W(Load 100Ω) | |
Power Consumption: | 800VA±10% | |
Surgery Type | For Variety of Operations , Endoscopy | |
Dimension L*W*H | 380mm*380mm*160mm | |
Weight | 10kg |
Standard Configuration | ||
Description | Quantity | Picture |
High frequency Electrosurgical unit | 1 |
|
Power Cable | 1 |
|
Disposable electrosurgical control pencil | 5 |
|
Disposable electro plate | 1 | |
Bipolar forceps | 1 |
|
Single foot step | 1 |
|
Double foot step | 1 |