Feature:

1. 6 Standard parameters: ECG, 2-TEMP, NIBP, SpO2, RESP, PR/HR

2. 12 inch high resolution color TFT LCD display

3. Real time S-T segment analysis, pace-maker detection

4. Indication of incorrect manipulation and malfunction analysis

5. Patient info input management function

6. Multi-lead ECG waveforms display in phase

7. Large volume of tabular and graphic trends information storage and easy to recall

8. Capture dynamic waveforms

9. Up to 2 hours working capacity of built-in rechargeable lithium battery

10. Unique accessory management cabinet

11. Networking capacity

12. Option: IBP, 24BP, ETC02, Built-in recorder, cart, wall shelf

Availability:
  • XRME220208341

  • XINDRAY

Factory Multi-parameter Patient Monitor

5

Feature:


1. 6 Standard parameters: ECG, 2-TEMP, NIBP, SpO2, RESP, PR/HR

2. 12 inch high resolution color TFT LCD display

3. Real time S-T segment analysis, pace-maker detection

4. Indication of incorrect manipulation and malfunction analysis

5. Patient info input management function

6. Multi-lead ECG waveforms display in phase

7. Large volume of tabular and graphic trends information storage and easy to recall

8. Capture dynamic waveforms

9. Up to 2 hours working capacity of built-in rechargeable lithium battery

10. Unique accessory management cabinet

11. Networking capacity

12. Option: IBP, 24BP, ETC02, Built-in recorder, cart, wall shelf


Specification:


Quality Standards and Classification

CE. ISO13485

SFDA: Class II b

Anti-electroshock degree

Class I equipment

(internal power supply

TEMP/Spo 2/NIBP: BF

ECG/Resp: CF

Application Range

Adult/Pediatric/Neonatal/Medicine/Surgery/

Operating Room/ICU/CCU

Display

12.1’real color TFT screen

Resolution: 800*600

One alarm indicator(yellow/red)

One working indicator(green)

One battery charge state indicator(green

Three modes in accordance with the alarm state

Environment

Operating environment

Temperature: 0-40℃

Humidity <=85%

Altitude -500~4600m

Transport and Storage environment

Temperature: -20-60℃

Humidit ≤93%

Altitude. -500~13100m

Power Requirements

AC:100~240V,50Hz/60Hz

DC: Built-in rechargeable battery

Battery: 4000MA 11.1V lithium battery

2h operating after full charge(one piece

5min operating after low battery alarm

Dimension and Weight

Equipment:

305mm×160mmx287mm;3.8kg

Package.

380mm x350 mm x 300mm: 6.1 kg

Date Storage

Trend diagram/table: 7x24h

NIBP review.

400 events

Wave review

100min

Alarm review.

100 alarm events

Support drug concentration titration analysis

ST Segment

ST Segment Range: -2.0mv-+2.0mv

Accuracy.0.02mV

NOTE: The specifications are subject to changes without pnor notice

ECG

5 Leads: RA. LA LL RL V

Lead mode I II III AVR. avL, AVF V

Increase: x250. x500. x1000. x2000

Sensitivity: >200 uv(peak-to-peak value)

Input impedance: >5( megohm)

Bandwidth: Surgery 1-20 HZ

Monitor 0.5-40 HZ

Diagnostic 0.05- 130 Hz

CMRR:≥100dB

Polarization Voltage: 土300mv

Baseline Recovering Time: After defibrillation< 3 seconds

Signal Range 8 mv(peak-to-peak value

Calibrating Signal: 1mv, precision 土5%

RESP

Method: RA-LL impedance

Resp Impedance range: 0.3-3Ω

Base Impedance range: 200Ω-4000Ω

Bandwidth. 0.1-2。5HZ

Resp rate: Adult

0-120BRPM

Neonatal/Pediatric 0- 150BRPM

Resolution: 1BRPM

Precision:±2BrPM

Asphyxia Alarm: 10-40 seconds

NIBP

Method:Pulse wave oscillometer

Work mode: Manual/Auto/STAT

Measure interval of auto mode

1,2,3,4,5,10,15,30,60,90,120,180,240,480 minute(s

Measuring Time of STAT Mode: 5 minutes

PR range: 40 -240bpm

Measure&alarm range: Adult

SYS 40-270mmhg

DIA 10~215mmHg

MEAN 20-235mmhg

Pediatric

SYS 40-200mmhg

DIA 10-150mmhg

MEAN 20-165mmhg

Neonatal

SYS 40-135mmhg

DIA

10~100mmHg

MEAN 20-110mmhg

Static pressure range: 0-300mmhg

Precision:±3mmHg

Pressure precision:

Max average error: 土5mmhg

Pressure precision

Max average error: 土5mmhg

Max. standard deviation:土8mmhg

Overvoltage protection

Adult 300mmhg

Pediatric 240mmhg

Neonatal 150mmhg

Spo2

Range: 0-100%

Resolution: 1%

Precision: 70%-100% 土2 DIGIT

0%-69%: 土no definition given

Pulse Rate

Range: 20- 300bpm

Resolution: 1bpm

Precision:±3bpm

Standard accessories

NIBP cuff tube

ECG cable&electrodes

Spo2 sensor

TEMP probe

Lithium-ion battery

Power cable

Operators manual

IBP

Label ART. PA. CVP. RAP LAP ICP P1 P2

Measuring and alarm range

ART 0-300 mmhg

PA -6-120 mmhg

CVP/RAP/LAP/ICP-10-40 mmhg

P1/P2 -10~300mmHg

Press Sensor

Sensitivity 5uv/V/mmhg

Impedance 300-3000Ω

Resolution 1 mmhg

Accuracy ±2%or±1mmHg, which great

Actualization interval: about 1 Sec

Co2

Side/Main stream

Warm-up time

when the ambient temperature is 25 C, the carbon dioxide curve(capnogram)can be displayed within 20/15 seconds, and all the specifications can be fulfilled within 2 minutes

Measurement range

0-150mmHg.0-19.7%,0-20kPa(at760mmHg)

atmospheric pressure provided by the host

Resolution 0.1mmhg: 0-69mmhg

0.25mmhg: 70-150mmhg

Precision 0-40mmhg: 土2mmhg

41-70mmhg: 土5%(reading)

71-100mmhg: 土8%(reading)

101-150mmhg: 土10%(reading)

Respiratory rate range

0-150BPM

Respiratory rate accuracy: 土1 BPM


1.Packing&Shipping2.72.5Our certificate XINDRAY MIC证书 NEW








Previous: 
Next: 

Search

Categories

Contact us
No.21,Software Avenue,Nanjing,
Jiangsu Province, P. R. China.
Tel:0086-25-52651490
Phone:0086-13951721149
Fax:0086-25-52651490

Quick Links

Products Category

Contact Form

Contact us
© 2021 Xindray Medical International Co., Ltd.  All rights reserved.