0086-25-52651490        intl-market@xindray.com
Bedside ICU Patient Monitor in Hospital
Home » Products » Life Support Product » Patient Monitor » Bedside ICU Patient Monitor in Hospital

loading

Share to:
sharethis sharing button

Bedside ICU Patient Monitor in Hospital

Feature:

1.12.1 inch high resolution color TFT LCD display
2.Full touch screen selectable, more convenient for operation
3.Real time S-T segment analysis, pace-maker detection 3-level audio/visual alarming
4.Patient info input management function
5.Efficient resistance to interference of defibrillator and HF knife.
6.Lasting working capacity with built-in rechargeable lithium battery
7.400 groups of NIBP list, 6000 seconds ECG waveform recall, 60 alarm evens records recall, 7-day trend chart in storage
8.Flexible operate ETCO2 and dual IBP functions

Availability:
  • XRME220208345

  • XINDRAY

Bedside ICU Patient Monitor in Hospital

9

Feature:


1.12.1 inch high resolution color TFT LCD display
2.Full touch screen selectable, more convenient for operation
3.Real time S-T segment analysis, pace-maker detection 3-level audio/visual alarming
4.Patient info input management function
5.Efficient resistance to interference of defibrillator and HF knife.
6.Lasting working capacity with built-in rechargeable lithium battery
7.400 groups of NIBP list, 6000 seconds ECG waveform recall, 60 alarm evens records recall, 7-day trend chart in storage
8.Flexible operate ETCO2 and dual IBP functions


Specification:



Screen is detachable

Separate module,stable performance

E10,E12,E15

Piug-in type patient monitor

Monitor ecg,spot,nibp,resp,temp,pr and hr

TECHNICAL SPECIFICATIONS

Quality Standards and Classification

CE. ISO13485

SFDA: Class II b

Anti-electroshock degree

Class I equipment

(internal power supply

TEMP/Spo 2/NIBP: BF

ECG/Resp: CF

Application Range

Adult/Pediatric/Neonatal/Medicine/Surgery/

Operating Room/ICU/CCU

Display

10’ 12.1 15’real color TFT touch screen

Environment

Operating environment

Temperature: 0-40℃

Humidity <=85%

Altitude -500~4600m

Transport and Storage environment

Temperature: -20-60℃

Humidit ≤93%

Altitude. -500~13100m

Power Requirements

AC:100~240V,50Hz/60Hz

DC: Built-in rechargeable battery

Battery: 4000MA 11.1V lithium battery

2h operating after full charge(one piece

5min operating after low battery alarm

Dimension and Weight

Equipment

E10:271mmx158mmx286mm:3.31kg

E12:303mmX160mmx287mm;3.78kg

E15:360mmx162mm×321mm;4.47kg

Package

E10:380mmx350mmx300mm;:5.6kg

E12: 380 mm x350 mm x 300mm; 6.1 kg

E15: 420 mm x380 mm x 321 mm: 7.3 kg

Date Storage

Trend diagram/table: 7x24h

NIBP review :400 events

Wave review. 100min

Alarm review 100 alarm events

Support drug concentration titration analysis

ST Segment

ST Segment Range: -2.0mv-+2.Omv

Accuracy 0.02mV

ECG

5 Leads: RA. LA LL RL V

Lead mode I II III AVR. avL, AVF V

Increase: x250. x500. x1000. x2000

Sensitivity: >200 uv(peak-to-peak value)

Input impedance: >5( megohm)

Bandwidth: Surgery 1-20 HZ

Monitor 05-40 HZ

Diagnostic 0.05- 130 Hz

CMRR:≥100dB

Polarization Voltage: 土300mv

Baseline Recovering Time: After defibrillation< 3 seconds

Signal Range 8 mv(peak-to-peak value

Calibrating Signal: 1mv, precision 土5%

RESP

Method: RA-LL impedance

Resp Impedance range: 0.3-3Ω

Base Impedance range: 200Ω-4000Ω

Bandwidth. 0.1-2。5HZ

Resp rate: Adult

0-120BRPM

Neonatal/Pediatric 0- 150BRPM

Resolution: 1BRPM

Precision:±2BrPM

Asphyxia Alarm: 10-40 seconds

NIBP

Method:Pulse wave oscillometer

Work mode: Manual/Auto/STAT

Measure interval of auto mode

1,2,3,4,5,10,15,30,60,90,120,180,240,480 minute(s

Measuring Time of STAT Mode: 5 minutes

PR range: 40 -240bpm

Measure&alarm range: Adult

SYS 40-270mmhg

DIA 10~215mmHg

MEAN 20-235mmhg

Pediatric

SYS 40-200mmhg

DIA 10-150mmhg

MEAN 20-165mmhg

Neonatal

SYS 40-135mmhg

DIA

10~100mmHg

MEAN 20-110mmhg

Static pressure range: 0-300mmhg

Precision:±3mmHg

Pressure precision:

Max average error: 土5mmhg

Pressure precision

Max average error: 土5mmhg

Max. standard deviation:土8mmhg

Overvoltage protection

Adult 300mmhg

Pediatric 240mmhg

Neonatal 150mmhg

Spo2

Range: 0-100%

Resolution: 1%

Precision: 70%-100% 土2 DIGIT

0%-69%: 土no definition given

Pulse Rate

Range: 20- 300bpm

Resolution: 1bpm

Precision:±3bpm

TEMP

Channel 2

Measure alarm range: 0-50℃

Resolution 0.1℃

Precision (no sensor): 土0.1℃

Standard accessories

NIBP cuff tube

ECG cable&electrodes

Spo2 sensor

TEMP probe

Lithium-ion battery

Power cable

Operators manual

Optional accessories

CO2 module

IBP module

Trolley bracket

Hanging bracket

Monitor recorder

IBP

Label ART. PA. CVP. RAP LAP ICP P1 P2

Measuring and alarm range

ART 0-300 mmhg

PA -6-120 mmhg

CVP/RAP/LAP/ICP-10-40 mmhg

P1/P2 -10~300mmHg

Press Sensor

Sensitivity 5uv/V/mmhg

Impedance 300-3000Ω

Resolution 1 mmhg

Accuracy ±2%or±1mmHg, which great

Actualization interval: about 1 Sec

CO2

Side/Main stream

Measurement Infrared radiation absorption technique

measurement range 0- 99mmhg

Precision 0-40mmhg土2mmhg

41~76mmHg±5mmHg

77~99mmHg±10mmHg

Resolution 1mmhg

Pumping rate

70ml/min. 100ml/min

Accuracy 15% or 15ml/min big

AWRR measuring range 0-120BRPM

Precision

0~70BrPM:±2BrPM

>70BrPM:土5BrPM


1.Packing&Shipping2.72.5Our certificate XINDRAY MIC证书 NEW








Previous: 
Next: 

Search

Categories

Contact us
No.21,Software Avenue,Nanjing,
Jiangsu Province, P. R. China.
Tel:0086-25-52651490
Phone:0086-13951721149
Fax:0086-25-52651490

Quick Links

Products Category

Contact Form

Contact us
© 2021 Xindray Medical International Co., Ltd.  All rights reserved.