1. 12.1"LED touch screen, handwriting pen
2. SD card port, USB port, convenient handle, multiple mounting solutions
3. IPX1 level waterproof cabinet design & sturdy housing to withstand rough handling
4. Over 13 kinds of arrhythmia analysis and alarm event review, hypoxemia report recording
5. Review and print 200 alarm events of arrhythmia and 2,000 groups of NIBP data;120hrs trend graph review.
6. Safe, stable and reliable. Nice and neat interfaces to monitor more parameters. Mass storage, power-off autosave function.
Availability: | |
---|---|
XRME220208347
XINDRAY
Feature:
1. 12.1"LED touch screen, handwriting pen
2. SD card port, USB port, convenient handle, multiple mounting solutions
3. IPX1 level waterproof cabinet design & sturdy housing to withstand rough handling
4. Over 13 kinds of arrhythmia analysis and alarm event review, hypoxemia report recording
5. Review and print 200 alarm events of arrhythmia and 2,000 groups of NIBP data;120hrs trend graph review.
6. Safe, stable and reliable. Nice and neat interfaces to monitor more parameters. Mass storage, power-off autosave function.
Specification:
Screen is detachable
Separate module,stable performance
E10,E12,E15
Piug-in type patient monitor
Monitor ecg,spot,nibp,resp,temp,pr and hr
Quality Standards and Classification
CE. ISO13485
SFDA: Class II b
Anti-electroshock degree
Class I equipment
(internal power supply)
TEMP/Spo2/NIBP: BF
ECG/Resp: CF
Application Range
Adult/Pediatric/Neonatal/Medicine/Surgery/
Operating Room/ICU/CCU
Display
10”,12.1”,15" real color TFT touch screen
Environment
Operating environment
Temperature: 0-40 C
Humidity:≤85%
Altitude
-500~4600m
Transport and Storage environment
Temperature: -20-60℃
Humidit ≤93%
Altitude -500~13100m
Power Requirements
AC:100~240V、50Hz/60HZ
DC: Built-in rechargeable battery
Battery: 4000MA 111V lithium battery
2h operating after full charge(one piece
5min operating after low battery alarm
Dimension and Weight
Equipment:
E10:271mm×158mmx286mm;3.31kg
E12:303mmx160mmx287mm;3.78kg
E15:360mmX162mmx321mm;,4.47kg
Package
E10: 380 mm x350 mm x 300 mm 5.6 kg
E12:380mm×350mmx300mm;6.1kg
E15: 420 mm 380 mm x 321 mm 7.3 kg
Date Storage
Trend diagram/table: 7x24h
NIBP review 400 events
Wave review 100min
Alarm review 100 alarm events
Support drug concentration titration analysis
ST Segment
ST Segment Range: -2.0mv-+2.0mv
Accuracy 0.02mV
ECG
5 Leads: RA. LA. LL RL. V
Lead mode:I,Ⅱ,Ⅲ,aVR,aVL,aVF,V
Increase:×250、×500、×1000、×2000
Sensitivity: >200 uv (peak-to-peak value)
Input impedance: >5(megohm)
Bandwidth: Surgery 1- 20 HZ
Monitor 0.5-40 Hz
Diagnostic 0.05-130 HZ
CMRR:≥100dB
Polarization Voltage: +- 300mv
Baseline Recovering Time: After defibrillation <3 seconds
Signal Range 8 mv (peak-to-peak value)
Calibrating Signal: 1mv, precision +-5%
RESP
Method: RA-LL impedance
Resp Impedance range: 0.3-3 O
Base Impedance range: 2000-4000 O
Bandwidth: 0.1-2.5HZ
Resp rate: Adult
0-120BRPM
Neonatallpediatric 0-150BRPM
Resolution 1BRPM
Precision ±2BrPM
Asphyxia Alarm: 10-40 seconds
NIBP
Method Pulse wave oscillometry
Work mode: Manual/ Auto/ STAT
Measure interval of auto mode
1,2,3,4,5,10,15,30,60,90,120,180,240,480 minute(s)
Measuring Time of STAT Mode: 5 minutes
PR range: 40-240bpm
Measure alarm range: Adult
SYS 40-270mmhg
DIA 10~215mmHg
MEAN 20 -235mmhg
Pediatric
SYS 40-200mmhg
DIA 10-150mmhg
MEAN 20-165mmhg
Neonatal
SYS 40- 135mmhg
DIA 10~100mmHg
MEAN 20- 110mmhg
Static pressure range: 0-300mmhg
Precision:±3mmHg
Pressure precision
Max average error: ±5mmhg
Max standard deviation: ±8mmhg
Overvoltage protection
Adult 300mmhg
Pediatric 240mmhg
Neonatal 150mmhg
Spo2
Range: 0- 100%
Resolution: 1%
Precision: 70%-100%: ±2 DIGIT
0%-69%: ±no definition given
Pulse Rate
Range: 20-300bpm
Resolution: 1bpm
Precision:±3bpm
TEMP
Channel 2
Measure &alarm range: 0-50 ℃
Resolution
0.1℃
Precision(no sensor): +0.1 ℃
Standard accessories
NIBP cuff tube
ECG cable & electrodes
Spo2 sensor
TEMP probe
Lithium-ion battery
Power cable
Operator s manual
Optional accessories
CO2 module
IBP module
Trolley bracket
Hanging bracket
Monitor recorder
IBP
Label ART, PA. CVP RAP LAP CP P1 P2
Measuring and alarm range
ART 0-300 mmhg
PA -6~120mmHg
CVP/RAP/LAP/CP -10-40 mmhg
P1/P2 10~300mmHg
Press Sensor
Sensitivity 5 uv/V/mmhg
Impedance 300-3000
Resolution 1 mmhg
Accuracy ±2%or±1mmHg, which great
Actualization interval about 1 Sec
Co2
Side/Main stream
Measurement Infrared radiation absorption technique
measurement range 0- 99mmhg
Precision 0-40mmhg ±2mmhg
41~76mmHg±5mmHg
77~99mmHg±10mmHg
Resolution
1mmhg
Pumping rate
70ml/min. 100m/min
Accuracy
15% or 15ml/min big
AWRR measuring range 0-120BRPM
Precision
0~70BrPM:±2BrPM
>70BrPM:±5BrPM
Feature:
1. 12.1"LED touch screen, handwriting pen
2. SD card port, USB port, convenient handle, multiple mounting solutions
3. IPX1 level waterproof cabinet design & sturdy housing to withstand rough handling
4. Over 13 kinds of arrhythmia analysis and alarm event review, hypoxemia report recording
5. Review and print 200 alarm events of arrhythmia and 2,000 groups of NIBP data;120hrs trend graph review.
6. Safe, stable and reliable. Nice and neat interfaces to monitor more parameters. Mass storage, power-off autosave function.
Specification:
Screen is detachable
Separate module,stable performance
E10,E12,E15
Piug-in type patient monitor
Monitor ecg,spot,nibp,resp,temp,pr and hr
Quality Standards and Classification
CE. ISO13485
SFDA: Class II b
Anti-electroshock degree
Class I equipment
(internal power supply)
TEMP/Spo2/NIBP: BF
ECG/Resp: CF
Application Range
Adult/Pediatric/Neonatal/Medicine/Surgery/
Operating Room/ICU/CCU
Display
10”,12.1”,15" real color TFT touch screen
Environment
Operating environment
Temperature: 0-40 C
Humidity:≤85%
Altitude
-500~4600m
Transport and Storage environment
Temperature: -20-60℃
Humidit ≤93%
Altitude -500~13100m
Power Requirements
AC:100~240V、50Hz/60HZ
DC: Built-in rechargeable battery
Battery: 4000MA 111V lithium battery
2h operating after full charge(one piece
5min operating after low battery alarm
Dimension and Weight
Equipment:
E10:271mm×158mmx286mm;3.31kg
E12:303mmx160mmx287mm;3.78kg
E15:360mmX162mmx321mm;,4.47kg
Package
E10: 380 mm x350 mm x 300 mm 5.6 kg
E12:380mm×350mmx300mm;6.1kg
E15: 420 mm 380 mm x 321 mm 7.3 kg
Date Storage
Trend diagram/table: 7x24h
NIBP review 400 events
Wave review 100min
Alarm review 100 alarm events
Support drug concentration titration analysis
ST Segment
ST Segment Range: -2.0mv-+2.0mv
Accuracy 0.02mV
ECG
5 Leads: RA. LA. LL RL. V
Lead mode:I,Ⅱ,Ⅲ,aVR,aVL,aVF,V
Increase:×250、×500、×1000、×2000
Sensitivity: >200 uv (peak-to-peak value)
Input impedance: >5(megohm)
Bandwidth: Surgery 1- 20 HZ
Monitor 0.5-40 Hz
Diagnostic 0.05-130 HZ
CMRR:≥100dB
Polarization Voltage: +- 300mv
Baseline Recovering Time: After defibrillation <3 seconds
Signal Range 8 mv (peak-to-peak value)
Calibrating Signal: 1mv, precision +-5%
RESP
Method: RA-LL impedance
Resp Impedance range: 0.3-3 O
Base Impedance range: 2000-4000 O
Bandwidth: 0.1-2.5HZ
Resp rate: Adult
0-120BRPM
Neonatallpediatric 0-150BRPM
Resolution 1BRPM
Precision ±2BrPM
Asphyxia Alarm: 10-40 seconds
NIBP
Method Pulse wave oscillometry
Work mode: Manual/ Auto/ STAT
Measure interval of auto mode
1,2,3,4,5,10,15,30,60,90,120,180,240,480 minute(s)
Measuring Time of STAT Mode: 5 minutes
PR range: 40-240bpm
Measure alarm range: Adult
SYS 40-270mmhg
DIA 10~215mmHg
MEAN 20 -235mmhg
Pediatric
SYS 40-200mmhg
DIA 10-150mmhg
MEAN 20-165mmhg
Neonatal
SYS 40- 135mmhg
DIA 10~100mmHg
MEAN 20- 110mmhg
Static pressure range: 0-300mmhg
Precision:±3mmHg
Pressure precision
Max average error: ±5mmhg
Max standard deviation: ±8mmhg
Overvoltage protection
Adult 300mmhg
Pediatric 240mmhg
Neonatal 150mmhg
Spo2
Range: 0- 100%
Resolution: 1%
Precision: 70%-100%: ±2 DIGIT
0%-69%: ±no definition given
Pulse Rate
Range: 20-300bpm
Resolution: 1bpm
Precision:±3bpm
TEMP
Channel 2
Measure &alarm range: 0-50 ℃
Resolution
0.1℃
Precision(no sensor): +0.1 ℃
Standard accessories
NIBP cuff tube
ECG cable & electrodes
Spo2 sensor
TEMP probe
Lithium-ion battery
Power cable
Operator s manual
Optional accessories
CO2 module
IBP module
Trolley bracket
Hanging bracket
Monitor recorder
IBP
Label ART, PA. CVP RAP LAP CP P1 P2
Measuring and alarm range
ART 0-300 mmhg
PA -6~120mmHg
CVP/RAP/LAP/CP -10-40 mmhg
P1/P2 10~300mmHg
Press Sensor
Sensitivity 5 uv/V/mmhg
Impedance 300-3000
Resolution 1 mmhg
Accuracy ±2%or±1mmHg, which great
Actualization interval about 1 Sec
Co2
Side/Main stream
Measurement Infrared radiation absorption technique
measurement range 0- 99mmhg
Precision 0-40mmhg ±2mmhg
41~76mmHg±5mmHg
77~99mmHg±10mmHg
Resolution
1mmhg
Pumping rate
70ml/min. 100m/min
Accuracy
15% or 15ml/min big
AWRR measuring range 0-120BRPM
Precision
0~70BrPM:±2BrPM
>70BrPM:±5BrPM